Seismic requirements for piping
Web3.2.2 Functional Requirements 3.2.3 Fittings and End Connections ... 3.2.13.11 Multiple Pipe Runs 3.2.13.12 Seismic Requirements 3.2.13.13 Structural Attachments 3.2.14 Pipe … WebBuilding Seismic Separation Joints: Provided where pipe crosses building seismic separation joints above ground level. NFPA 13 2016 9.3.3.1 Four‐Way Braces Building Seismic Separation Joints: Upstream and downstream within 6‐ft of a …
Seismic requirements for piping
Did you know?
WebAny material, appliance, equipment, system or method of construction meeting the requirements of this code shall be approved in writing after satisfactory completion of the required tests and submission of required test reports. 1703.3Record of approval. WebMuch of British Columbia and parts of other provinces are in strong seismic zones. ASME code calculations for expansion, flexibility and support for pipe diameters exceeding NPS 3.” ... Overpressure protection for piping follows the standards requirements of ASME B31.3 301.2.2: (a) Provision shall be made to safely contain or relieve (see ...
WebThis Standard establishes a method for the seismic design of above-ground, metallic piping systems in the scope of the ASME B31 Code for Pressure Piping (B31.1, B31.3, B31.4, B31.5, B31.8, B31.9, B31.11). Table of Contents WebPart of this mandate required stabilizing the mechanical and piping systems. To provide technical guidance for economical bracing methods, the Sheet Metal Industry Fund of Los …
Webpipe exemptions cont. seismic design category d, e, or f with a component importance factor of 1.0: seismic restraints are not required for pipes of a nominal size of 3” or less. asce 7-05 sec 13.6.8 (2b) seismic design category c with a component importance factor of 1.5: seismic restraints are not required http://gvrahe.org/wp-content/uploads/2013/11/Seismic-Wind-Restraint-Requirements-NY-11-7-13.pdf
WebThis section will determine the maximum allowable seismic restraint spacing for pipe and duct between the longitudinal seismic restraints. It will begin by examine the seismic …
WebApr 18, 2024 · Keep in mind that there are different requirements for pendent sprinklers where the maximum static or flowing pressure exceeds 100 psi. Unsupported armover – the horizontal length of an unsupported armover can’t exceed 24 inches (600mm) for steel pipe and 12 in (300 mm) for copper tube. meadowdale learning center feagin millWebJan 3, 2024 · Piping Seismic Analysis Basis. Lines with an outside diameter of 6” and larger. Transfer lines/Two-phase flow lines. Piping systems connected to Strain-sensitive … meadowdale learning center moodyWebSeismic protection for Schedule 40 or greater steel pipe inside buildings: Provide separate metered gas supply mains for building sections separated by a seismic joint. If … meadow day use areaWeblished Guidelines for Seismic Restraint of Mechanical Systems in 1976. This document was pre−approved by the Cali-fornia Office of Statewide Health Planning and Development (OSHPD). A later edition, in 1982, co−published by the Plumbing and Piping Industry Council, Inc. (PPIC), expanded the bracing guidelines for piping. For several years, meadow dreams pura vidaWebApr 18, 2024 · Keep in mind that there are different requirements for pendent sprinklers where the maximum static or flowing pressure exceeds 100 psi. Unsupported armover – … meadowdale high school staffWebSep 25, 2024 · The purpose of the flexible coupling is to allow for some additional flexibility in the vertical piping connecting the overhead sprinkler system to piping fixed to a lower level structure that could move differentially during a seismic event. The flexible couplings are required, regardless of the diameter of the pipe that drops from the ... meadowdale park beachWebJan 3, 2024 · Piping Seismic Analysis Basis The criteria for line selection for seismic analysis are normally mentioned in the ITB documents if the construction site falls under the seismic zone. If the same is not mentioned then the following lines can be considered: Lines with an outside diameter of 6” and larger. Transfer lines/Two-phase flow lines. meadowdale pee wee football